Energy Saving Compressor Telecom Air Conditioner , Outdoor Telecom Cabinet

Basic Information
Place of Origin: CHINA
Brand Name: CYNRIN
Certification: CE, CCC
Model Number: CCA005SA
Minimum Order Quantity: 1 sets
Price: USD300~3999 unit
Packaging Details: Wooden case package.
Delivery Time: 14 work days after payment
Payment Terms: T/T, D/A, D/P, L/C, Western Union, MoneyGram
Supply Ability: 10000 sets per Month

AC220V 500W Compressor Air Conditioner,For Outdoor Telecom Cabinet/Room

 

Product Characteristic

 

1. Description
 
The AC Compressor Air Conditioner is a full automation temperature control product. It uses intelligent controller to control the whole system of the air conditioner. According to the variation of environment temperature, the intelligent controller can automatically detect, operate and record the whole system’s operating time, power consumption, event and historical data. It can store 100 event records and 1280 historical data records, and can enquire 256 days’ daily record information. The product is widely applied in telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc. The air conditioner includes the following specs: 300W, 500W, 800W,1000W,  1500W, 2000W,2500W,3000W,3500W,4000W.  In addition, it also can be custom made.
 
The air conditioner uses utility power input, allowing wide voltage range (±30%), with higher efficiency. The air conditioner controller is digital display temperature controller, with easy operation and straight display. The controller has 6 relay outputs, which respectively control internal circulation fans, external circulation fans, cooling compressor, heater, hydrogen exhaust fan and a reserve output way. The controller has fault detection and alarm function and can transmit fault alarm signals to monitoring center.
 
2. Features
 
 
 
3. System Principle Diagram
 
 
TC06-160JFL/01,1600W AC220V Air Conditioner,For Outdoor Telecom Shelter/Room/Base Station
Diagram 1: System Principle Diagram
 
4. Standard Compliance 
 
 
Standard Description
GB/T 17626.7-1998 Electromagnetic compatibility
GB4706.1 Safety of household appliance and electrical appliance with similar use.
GB4798.1 Environmental conditions existing in the application for electric and electronic products - storage
GB4798.2 Environmental conditions existing in the application for electric and electronic products - transportation
GB4798.3 Environmental conditions existing in the application for electric and electronic products - usage

 

 

5. Technical Parameters

 

 

 

Environmental Performance

working environmental temperature -20°C ~ 55°C
storage working temperature -50°C ~ 70°C
working humidity ≤95%
Thermal Performance rated cooling capacity

800W(L35 L35)

heating input power 300(optional)

 

Electrical Performance

rated input current

2.35A(L35 L35)

rated input power

517W(L35 L35)

input voltage

AC220V/50Hz

(187V ~ 264V)

 

 

 

TC06-160JFL/01,1600W AC220V Air Conditioner,For Outdoor Telecom Shelter/Room/Base Station

Diagram 2: Dimension Diagram

 

6. Installation and Electrical Wiring
 
6.1 Preparation Before Installation
 
(1) Prepare the tools in the following table “Installation And Maintenance Tools”.
 
(2)Check the air vents to ensure there’s no unnecessary items on the vents.
 
 
6.2 Installation And Maintenance Tools
 
 
Tools Name Function
Cross Screwdriver Fix air conditioner.
Small Slotted Screwdriver Wire power supply port on the panel
Wire Stripper Wire stripping
Wire Crimper Crimp power supply for equipment
Multimeter Check the wiring to ensure it’s correctly connected and without short circuit.
Clamp Meter Test operating current of the air conditioner
 
6.3 Installation Steps
 
(1)Make sure the air conditioner is not connected with power.
(2)Fix the air conditioner according to the Dimension Diagram.
(3)Strip the insulation of the power supply wire, and crimp the terminal.
(4)Connect the wires according to the Electrical Wring Diagram.
(5)After finishing the wiring, use the multimeter to check if the electric circuit is normal. Then connect the air conditioner with power supply, and use clamp meter to test the operating current.
Note: Make sure to disconnect all the power supply to the air conditioner before installation. Choose proper wire diameter and test operating current according to the technical parameters of the air conditioner.
 
 
 
6. 4 Electrical Wiring Diagram
 
TC06-160JFL/01,1600W AC220V Air Conditioner,For Outdoor Telecom Shelter/Room/Base Station
Diagram 3 Electrical Wiring Diagram
 
Wiring Ports:
 
L N PE : power supply port (voltage input: 220VAC±25% 50/60Hz)
A+ B- GND : communication port
AL1 AL2: general alarm output port
F+ F- : direct ventilation output port
N : not connected pin
 
7. After mechanical installation and electrical installation are finished, check the installation items.
 
(1)Make sure the air conditioner is firmly installed.
(2)Check the electrical installation circuit, and ensure it doesn’t have short circuit.
(3)Check the air outlet, air inlet, internal fan and external fan of the air conditioner, and ensure they don’t have any odds and ends.
(4)Connect the air conditioner to power supply, and test the power supply (voltage input: 220VAC±25% 50/60Hz), operating current 1A±4%.
 
 
8. Technical Parameter
 
 
a. LCD display, user friendly;
b. Simultaneously display temperature and humidity inside the cabinet and communication room temperature;
c. Temperature measurement accuracy: 0.1 °C; humidity measurement accuracy:5%;
d. Can store 180 days’ daily event record, 1 record every day;
e. Daily highest temperature, lowest temperature, average temperature
f. Daily event record;
g. Store the former day’s daily data at 0:00 every day; Can enquire 180 days’ daily record information;
h. RS485 communication, RTU-Modbus protocol, support remote detection and control;
i. Controllable air conditioner quantity: 2 sets. 1 set of air conditioner for communication room, and 1 set of small air conditioner for thermostatic cabinet.
j. Control mode: pulse (Non dry contact air conditioner), conducting (dry contact air conditioner)
k. Real-time control air conditioner on/off
l. Power supply: AC85V~265V/50HZ;
m. Power consumption:≤5W;
n. Working environment: -30°C~70°C;<90%RH;
o. Installation method: guide rail,hanging;
p. Dimension: 352*175*583mm
 
 
 

Specification sheet

 

 

 

Place of Origin: Shenzhen, China (Mainland) Rated Cooling Capacity : 800W
Brand Name: CYNRIN Rated Heating Capacity:500W(optional)
Model: CCA008SA Dimension: H×W×D 352*175*583mm
Product Name: Outdoor Cabinet Air Conditioner Input Voltage: AC220V/50Hz
Certification: ISO9001, CE, 3C,  Rated Input Current: 2.2A
Cover Material: galvanized steel Rated Input Power: 484W
Color: grey Working Temperature: -20°C ~ +55°C
Protection Level: IP55 Noise: ≤64dB
Installation Mode: door mounted Refrigerant: R410a
Support OEM Cooling Method: compressor, active cooling

 

 


Product details

 

 

Energy Saving Compressor Telecom Air Conditioner , Outdoor Telecom Cabinet

 

 

Energy Saving Compressor Telecom Air Conditioner , Outdoor Telecom Cabinet

 

 

 

 

 

Dimension Diagram: H×W×D: 352*175*583mm

 

 

 

Energy Saving Compressor Telecom Air Conditioner , Outdoor Telecom Cabinet

 

 

 

 

Installation Diagram

 

 

Energy Saving Compressor Telecom Air Conditioner , Outdoor Telecom Cabinet


 
 



Application 

 

The products are widely used in

 

Energy Saving Compressor Telecom Air Conditioner , Outdoor Telecom Cabinet

 

Payment & Shipping Terms:

 

 

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: T/T, L/C, etc
Supply Ability: 1,0000 sets per month
Delivery Time: 10-15 working days
Packaging Details: carton + wooden case + pallet
 

 

 

 

Energy Saving Compressor Telecom Air Conditioner , Outdoor Telecom Cabinet

 

 

 

 

 

FAQ

 

 

1. Q: How about the air cooler material?

    A: It makes by 100% new plastic, pure copper for motor.

 

2. Q:  What voltages you can do, could you make special voltages?

    A:  we can make DC48  and all AC voltage products for you.

 

3. Q: I want to use our own brand, is it OK?

    A:  It is possible, we supply the OEM products too. 

 

4. Q: How about the warranty?

    A:  All the unit warranty is one year.

 

 

 

 
 

Contact Details